FIGURE 1. For a quick estimate of penetration depth when using a urethane pad, you can add the punch radius (r), material thickness (t), and a safety clearance buffer (tr) added to each side of the radius: r + tr + tr + t. Note that this is not a valid radius substitution. Again, this is a quick estimate, not a precise calculation.
Over the last couple of months we have been reviewing urethane press brake tooling, including low-durometer (soft pads) and high-durometer (hard-tool profiles) varieties. If you use a pad, its volume needs to be at least 10 times that of the penetrating punch and material.
Roughly calculating the volume of the penetrating punch and material is straightforward; precisely calculating it is another matter. I’ll cover the rough method here. Practically speaking, most shops don’t run into problems, especially for short production runs, provided they use reasonable pad sizing and avoid excessive compression. In certain circumstances, you might need a more precise approach. Regardless, used correctly, the rough method gives you a workable estimate—as long as you’re not pushing the limits of your urethane pads.
How Urethane Degrades
You might be able to use pads smaller than 10 times the volume of the penetrating punch and material. Doing so, however, is not the best option and may not produce the highest-quality parts. You will overwork the pad, causing hysteresis. Pronounced “his-tuh-ree-sis,” hysteresis is the internal resistance of the urethane to repeated deformation, which causes heat buildup during heavy or continuous forming cycles. The phenomenon refers to the lag between the applied force and the urethane’s elastic recovery after the pad has been released from pressure. Urethane exhibits both elastic (spring-like) and viscous (fluid-like) characteristics.
When urethane is compressed during forming, not all the energy used to deform it is immediately recovered, and some of it is lost as internal friction. That internal friction is what generates heat. Repeated or excessive use without adequate cooling time leads to cumulative heat buildup inside the pad. Over time, this can soften the urethane, degrade its mechanical properties, and shorten its life.
The Rough Approach
Imagine we’re working with a 12-in. bend length in 0.125-in.-thick material. You have a punch with an angle of 90 degrees and a nose radius of 0.125 in. You need to know the penetrating volume, or the amount of urethane displaced by the punch tip during forming.
To calculate this, you can use a geometric approximation based on the shape of the punch tip and its depth of penetration into the urethane. The following formula gives you the total penetrating volume in cubic inches. A1 is the nose radius while A2 is the bend length, both measured in inches:
Penetration Volume = 0.25 × π × A12 × A2
So, a 12-in. bend with a 0.125-in. punch nose radius equals 0.1472 cu. in. The minimum pad volume needs to be 10 times that value—or 1.47 cu. in. Notice something missing? Yes, this calculation does not include the material thickness. You would think that all you need to do is add the 0.125-in. punch radius to the 0.125-in.-thick material, right? (In this case, A1 in the formula would be 0.250 in.—punch nose radius plus the material thickness).
This works fine if you’re only roughly estimating displaced volume. So, if you’re performing quick tooling clearance checks or want to check safety margins, or if you have generous design scenarios in which an imprecise volume measurement won’t cause failure, a rough estimate might be enough.
Avoid Bottoming Out
You need to ensure your pad is deep enough for the application. To start, you can estimate the penetration depth with what’s known as the “clearance-stack” concept:
Penetration depth estimate = r + tr +tr + t
where r is the punch nose radius; tr is a thickness added to each side of the radius, for clearance and safety; and t is the material thickness. This isn’t a formal equation. Rather, it is conceptual in nature, helping to illustrate how the material and tooling interact. This quick estimation still can work effectively, especially when that extra clearance (tr) is included. Note that the tr figure is not literal; it’s just a rule-of-thumb offset that accounts for arc engagement—that is, the curve of the punch tip making contact—and elastic deformation. In most setups, tr values between 0.040 to 0.060 in. tend to work well. Doubling the tr value (that is, tr + tr) ensures clearance on both sides of the punch radius, which can be especially important when estimating worst-case or maximum displacement. The values are based on practical shop floor experience and essentially help keep you out of trouble during quick pad-height estimations.
Figure 1 gives you a visualization of the concept. This isn’t about precise geometry. It’s just a quick method to ensure the punch doesn’t overcompress the pad or bottom out.
Let’s say our punch radius (r) is 0.125 in. and the material thickness (t) is 0.090 in. In this case, we establish the safety clearance (tr) at 0.050 in. (starting at a midpoint between 0.040 and 0.060, to keep the math simple). This gives us the following:
0.125 + 0.050 + 0.050 + 0.090 = 0.315 in.
The actual penetration depth may be closer to 0.200 in., but this conservative estimate of 0.315 in. gives you a buffer for safety. Again, this is just a rule of thumb, not precise geometry.
To avoid bottoming out, reduce heat buildup, and extend pad life, your urethane pad should be at least two- to two-and-a-half-times thicker than the estimated penetration depth. If your clearance stack calculates a depth of 0.315 in., you’d want a urethane pad thickness of at least 0.75 to 1.00 in.